SikaBit ® PRO P40-10 PE RT
SikaBit ® PRO P40-10 PE RT is a kind of hot melt roof of APP modified asphalt waterproofing materials, contains root resistant agent, can make the coil direct contact with soil.With stable size non-woven polyester inline content enhancement, and glass fiber is stable.Bottom with polyethylene hot melt film, easy to use.
- About 4 mm thickness
- The surface appearance: polyethylene film
- There are still good elasticity - 10 ° C
- Humic acid resistant and chemical fertilizer
- The plant root injury
- Good water tightness
- High tensile strength
- High elongation and low temperature flexibility
- Good impact resistance
- Easy to use the torch heating installation
- According to the base material selected primers and weather conditions
Using range
Waterproof membrane can be used to:- Protective layer or layer pressure under the flat roof
- A rooftop garden
- Falling roof landscape beautification
- To protect the roof pressure layer
- The waterproof layer of roof garden in contact with the soil
- The basement
Feature/advantages
- About 4 mm thickness
- The surface appearance: polyethylene film
- There are still good elasticity - 10 ° C
- Humic acid resistant and chemical fertilizer
- The plant root injury
- Good water tightness
- High tensile strength
- High elongation and low temperature flexibility
- Good impact resistance
- Easy to use the torch heating installation
- According to the base material selected primers and weather conditions
packaging
The coil size |
|
The length of the |
10.00 m |
The width of the |
1.00 m |
color
The surface layer |
Polyethylene film |
backing |
Polyethylene film |
Technical information
Certification/standard
- The performance of the CE marking EN 13707 statement - used in roof waterproof reinforced asphalt slab
- CE mark EN 13969 performance statement - waterproof elastic plate - tar moistureproof board
- Root resistance EN 13948, EN 13707, SikaBit ® PRO P40-10 PE RT, Hochschule Geisenheim University, the test report
Chemical composition
APP modified asphalt, contains root resistant agent
Reinforcement material
With glass fiber and steady polyester non-woven fabrics
The best life
Since the production within 36 months
Storage conditions
Products should be original stored in + 5 ° C to + 35 ° C in the dry environment.Vertical placement.In the process of transportation or storage, do not use the coil of the pallet stacked on top of each other, or stacked in any other material of the pallet.Please refer to the packing instructions.
The length of the
10 m + / - 1.0% |
(EN 1841-1) |
The width of the
1 m + / - 1.0% |
(EN 1841-1) |
Effective thickness
4.0 mm + / - 5% |
(EN 1849-1) |
Impact resistance
P 700 mm + 23 ° C |
(EN 12691 - Method A) |
The tensile strength
|
(EN12311-1) |
elongation
|
(EN12311-1) |
Tear strength
|
(EN12310-1) |
Joint shear resistance
|
(EN12317-1) |
Cold bending
- 10 ° C |
(EN 1109). |
Flow resistance sex
110 ° C or higher |
(EN 1110). |
Water tightness
60 kPa |
(EN 1928 - Method B) |
External fire performance
F roof |
(EN 13501-5) |
In case of fire response
Class E |
(EN 13501-1) |
applied
Environmental atmospheric temperature
+ 5 ° C to + 50 ° C
Air relative humidity
Up to 80%
Element to temperature
+ 5 ° C to + 50 ° C
Element to quality
Base material must have enough strength to new and existing construction waterproof layer.Used as the roof membrane, it must be designed and fixed the roof system, to wind uplift loading.Base material must be uniform and solid, smooth, no sharp protrusion or burr, clean, dry, no oil, asphalt, oil, dirt and loose adhesion of particles
Element to organize
Using the appropriate equipment to base material preparation to the required quality